Article
A High-Throughput Microphysiological Liver Chip System to Model Direct and Idiosyncratic Drug-Induced Liver Injury Using Human Liver Organoids
2023-12-04
Abstract excerpt
1. <h4>Objective</h4> Drug-induced liver injury (DILI) is a major failure mode in pharmaceutical development. This study aims to address the limitations of existing preclinical models by introducing a high-throughput, microfluidic liver-on-a-chip system, termed as “Curio Barrier Liver Chips,” seeded with human liver organoids to enable metabolic and phenotypic morphologic characterization. <h4>Methods</h4> Curio...
Topics
Open a Topic to create a Post that cites this publication.
Identifiers and source
- Literature Corpus work
- 5b1cf4cf-2694-567d-8026-ed6820da05fd
- DOI
- 10.1101/2023.12.01.569575