HPLC method for rapid determination of acetylator phenotype by measuring urinary caffeine metabolites.
Journal of pharmaceutical and biomedical analysis - 1 Oct 1993
Klebovich I, Arvela P, Pelkonen O
Abstract excerpt
A validated reversed-phase high-performance liquid chromatographic (RP-HPLC) method is developed for the selective and rapid determination of two major metabolites of caffeine, namely 5-acetylamino-6-formylamino-3-methyluracil (AFMU) and 1-methylxanthine (MX) from human urine. HPLC separation is achieved by means of a Supersphere-60 RP-Select B (4 microns) analytical column using a non-linear gradient elution...