MscS inactivation and recovery are slow voltage-dependent processes sensitive to interactions with lipids.
Biophysical journal - 16 Jan 2024
Britt Madolyn, Moller Elissa, Maramba Joseph, Anishkin Andriy, Sukharev Sergei
Abstract excerpt
Mechanosensitive channel MscS, the major bacterial osmolyte release valve, shows a characteristic adaptive behavior. With a sharp onset of activating tension the channel population readily opens, but under prolonged action of moderate tension it inactivates. The inactivated state is non-conductive and tension insensitive, which suggests that the gate becomes uncoupled from the lipid-facing domains. Because the...