Article
HLA-B allele dropout in PCR sequence-specific oligonucleotide probe typing due to intronic polymorphism in the novel B*58:01:01:02 allele.
International journal of immunogenetics - 1 Jun 2016
He Y, Wang W, Han Z, He J, Chen N, Dong L, Tao S, Zhang W, He J, Zhu F, Lv H
Abstract excerpt
Currently, Luminex technology based on the PCR sequence-specific oligonucleotide (SSO) probe method has been widely used for HLA genotyping in the immunogenetics laboratories. Here, we reported a case with HLA-B allele dropout by Luminex technology. The initial HLA-B result of the Luminex method with a commercial agent kit was inconclusive, and then, the result of PCR-SBT technology indicated the dropout as a...