Abstract excerpt
<h4>Objectives: </h4> To assess the probability of survival of crowns made of high translucent 3 rd generation zirconia (Prettau Anterior - PA), 2 nd generation zirconia (Prettau - P), and the glass-ceramic lithium disilicate (IPS e.max CAD - EM). <h4>Materials: </h4> and Methods: CAD-CAM premolar crowns were fabricated with occlusal thicknesses of 1.0 mm or 1.5 mm and cemented on a metal dye. Step-stress acceler...