Tips for preventing hematoma and infection after pacemaker implantation

2025-04-22

Abstract excerpt

<title>Abstract</title> <p><bold>Background:</bold> The purpose of the study was to identify the clinical factors associated with hematoma formation after PM or ICD device implantation and how to prevent it. <bold>Methods:</bold> Fifty patients (group 1) were subjected to local measures such as electrocautery use and intra-pocket hydrogen peroxide (3%, diluted 50% with NaCl) application. Fifty other patients (gro...