Back to search

Article

Super-Resolution Ultrasound Localization Microscopy using High-Frequency Ultrasound to Measure Ocular Perfusion Velocity in the Rat Eye

2023-04-17

Abstract excerpt

Imaging of the ocular vasculature can provide new insights into the pathophysiology of ocular diseases. This study proposes a novel high-frequency super-resolution ultrasound localization microscopy (SRULM) technique and evaluates its ability to measure in vivo perfusion changes in the rat eye at elevated intraocular pressure (IOP). A 38.4 MHz center frequency linear array transducer on a VisualSonics Vevo F2 imag...

Topics

Open a Topic to create a Post that cites this publication.

Identifiers and source

Literature Corpus work
8e4fe56f-4b48-5581-b56f-4db4abcaaea3
DOI
10.20944/preprints202304.0433.v1
Open publication

Related research

Semantic proximity does not establish scientific evidence.

Click a neighbor to travelStep 1 · 12 closest
Interactive article relationship graphSelect a related publication card to move it into the centre and load its closest explainable connections. Solid lines are source-backed structured connections. Dashed lines are semantic discovery signals and are not scientific evidence.
Super-Resolution Ultrasound Localization Microscopy using High-Frequency Ultrasound to Measure Ocular Perfusion Velocity in the Rat EyeDOI 10.20944/preprints202304.0433.v1