Effect of Surgical Tightening Torque on the Pull-Out Strength of Screws in Vertebral Body Tethering

2025-09-05

Abstract excerpt

<h4>Background: </h4> /Objectives: Screw loosening and vertebral fractures remain common after vertebral body tethering (VBT). Because tightening torque sets screw preload, its biomechanical effect warrants explicit modeling. In this paper, a Finite Element (FE) model, supported by ex-vivo porcine vertebrae tests, was developed and validated that incorporates torque-induced pre-tension to quantify vertebral stress...

Topics

Open a Topic to create a Post that cites this publication.

Identifiers and source

Literature Corpus work
1afa51ed-b778-5486-be14-c724abcb32be
DOI
10.20944/preprints202509.0524.v1
Open publication

Related research

Semantic proximity does not establish scientific evidence.

Click a neighbor to travelStep 1 · 12 closest
Interactive article relationship graphSelect a related publication card to move it into the centre and load its closest explainable connections. Solid lines are source-backed structured connections. Dashed lines are semantic discovery signals and are not scientific evidence.
Effect of Surgical Tightening Torque on the Pull-Out Strength of Screws in Vertebral Body TetheringDOI 10.20944/preprints202509.0524.v1