[Comparison of clinical usefulness of immunophenotyping of leukemia using the immunofluorescence and immunoenzyme APAAP methods].
Acta haematologica Polonica - 1 Jan 1992
Stella-Hołowiecka B, Jagoda K, Koehler M, Krzemień S, Hołowiecki J
Abstract excerpt
The clinical utility of the indirect immunofluorescence (IF) and the alkaline phosphatase-anti-alkaline phosphatase (APAAP) techniques was compared in 103 newly diagnosed acute leukaemia patients immunophenotyped using a panel of 19 monoclonal antibodies (MoAb). In spite of slight variations in the percentages of cells reacting with particular MoAbs when comparing the two methods we found no discrepancies in the...